Providing Temperature Uniformity Survey solutions to efficiently cater for 130 Heat Treat Furnaces needs a specialized solution! Shane Filer from Neal Systems (a Eurotherm distributor) describes how this was achieved by utilizing advanced products from Invensys Eurotherm and Wonderware.

(Guest Blog) Shane Filer Vice President of Sales and Marketing at Neal Systems Incorporated (NSI).

A Customized Thermal Uniformity Survey Solution for a 130 Heat Treat Furnace Plant

The AMS2750 standard is very important for metals treating plants that are participating in NADCAP industries. Specifically, thermal uniformity surveys (TUS) with the appropriate reporting is often an expensive but necessary requirements for plants that must prove compliance to NADCAP standards.  For a metals treating plant with 130 furnaces, a team of engineering, maintenance, and quality had a major challenge performing the surveys quarterly, maintaining the equipment, and producing the appropriate reports.

Neal Systems had originally presented this plant with Invensys Eurotherm’s Chessell 6000 series recorder with TUS reporting package.  The plant was initially elated, but upon further testing, found that they needed even more customization and automation than the package offered.  For instance, some furnaces were programmed around degrees Fahrenheit, while others were degrees Celsius.  There were approximately 40 different furnace TUS test setups, with anywhere from 6 to 40 thermocouples.  The types of thermocouples differed significantly, including S, N, T, and K.  Some of the furnaces required door tests, where the supplier wanted to verify the response of the furnace to doors being opened and closed.  The whole system would have to be highly mobile, simple to use for the maintenance team, accurate enough to meet the extremely tight accuracy levels required by the AMS2750 standard, and highly automated from selecting a furnace to printing a final TUS report.

A Eurotherm distributor, Neal Systems, was able to produce a design based around the Invensys Eurotherm 2550 series control and I/O package in a mobile thermocouple data collector coupled with an Invensys Wonderware SCADA screen with historian for furnace test interface and report printouts.

When the maintenance team needed to run a test report, they would select from one of two “thermocouple pods” that most closely matched the type of thermocouple inputs needed for that test run.  After connecting all of the test thermocouples to the appropriate pod, they would then take a laptop loaded with the custom Wonderware interface, and connect to the pod.  The interface would allow them to enter all of their pertinent data to the run, select a pre-configured “furnace characterization” (one for each of the 130 furnaces, with the correct number and type of thermocouples along with anything else special for the furnace), and then start their run.  From a quality control standpoint, the custom interface included intelligence to show which pod was active (and which one was not), which thermocouples were active, and compare that to the furnace characterization in question to verify everything was a match.  Preconfigured alarms would provide warning at each level should any of the thermocouples show a reading outside of the acceptable band.  A custom calibration interface provided the ability to check and recalibrate all channels quarterly to ensure accuracy standards are maintained.

To date, the systems have been used to run many hundreds of TUS reports, saving the company extensive time and money and allowing full compliance with the NADCAP standards.  The reports produced are stored locally on each laptop and also linked to a central database for ease of storage and review when necessary, should an auditor request original data proof.

For more information on specific Temperature Uniformity Solutions (TUS) for AMS2750E requirements.

To learn more about Neal Systems (Newtown, PA), please visit www.nealsystems.com.

Get the most from your process

12 Key Changes from AMS2750D to AMS2750E

Why Eurotherm Materials Processing Solutions?

> Discover our Heat Treatment solutions today

Nadcap compliance statement for Eurotherm products

Eurotherm Heat Treat Solutions with Peter Sherwin

Selecionador de produtos

Package icon
Você precisa de ajuda para escolher o produto certo?

Nossa ferramenta irá combinar o melhor produto para suas necessidades

Iniciar selecionador de produtos

Contete-Nos

close
close