- Home - Site Map - Links - Contact Us - About Us - Get In The Loop Search our site:  

TECHNICAL SPECIFICATIONS
Output 1.00 to 1.20 Vdc over operating range.
   
Readout % oxygen sensors should be used with controlling, recording and indicating instruments having an input impedance of 8 megohms or higher.
   
Immersion Depth 3 inches minimum.
   
Thermal and Mechanical Shock The special alloy outer protection tube protects against both thermal and mechanical shock. As with any precision instrument, take reasonable care when handling and installing.
   
Accuracy ±0.05 weight percent carbon in normal operating range.
   
Weight 3 pounds, 5 ounces.
   
Response Time Less than 1.0 second.
   
Reference Air Uncontaminated air at maximum rate of 236 cc per minute=0.5 SCFH (standard cubic feet per hour).
   
Protection Tube Special alloy is resistant to corrosion and oxidation up to 2012°F (1100°C).
   
Operating Temperature 1400°F (760°C) to 2012°F (1100°C).
   
Thermocouple Types K, R and S.
Last updated July 1, 2003