Output |
|
1.00 to 1.20 Vdc over
operating range. |
|
|
|
|
|
Readout |
|
% oxygen sensors
should be used with controlling, recording and indicating instruments having an
input impedance of 8 megohms or higher. |
|
|
|
|
|
Immersion Depth |
|
3 inches minimum. |
|
|
|
|
|
Thermal
and Mechanical Shock |
|
The
special alloy outer protection tube protects against both thermal and
mechanical shock. As with any precision instrument, take reasonable care when
handling and installing. |
|
|
|
|
|
Accuracy |
|
±0.05 weight
percent carbon in normal operating range. |
|
|
|
|
|
Weight |
|
3 pounds, 5
ounces. |
|
|
|
|
|
Response
Time |
|
Less than 1.0
second. |
|
|
|
|
|
Reference Air |
|
Uncontaminated air at
maximum rate of 236 cc per minute=0.5 SCFH (standard cubic feet per hour). |
|
|
|
|
|
Protection Tube |
|
Special alloy is
resistant to corrosion and oxidation up to 2012°F (1100°C). |
|
|
|
|
|
Operating
Temperature |
|
1400°F (760°C) to 2012°F (1100°C). |
|
|
|
|
|
Thermocouple |
|
Types K, R and S. |