- Home - Site Map - Links - Contact Us - About Us - Get In The Loop Search our site:  

Dimensions (mm): 16-25A— 215H x 155W x 186D, 3.1kg
50-63A— 235H x 155W x 186D, 3.5kg
Load type: Resistive or short wave infrared
Inputs :
Logic (LGC): 5V or 10V, 20mA; ON >50%
OFF <25% of the nominal level
DC Current (4mA20): 4 to 20mA, input impedance 250ž
DC Voltage (0V5 or 0V10): 0 to 5V or 0 to 10V, input impedance 100kž
Potentiometer: 10kž (customer supplied)
Firing mode: Logic, Single Cycle, Fast Cycle, Slow Cycle
and Advanced Single Cycle
(4 or 6 wire load configuration)
Operating temperature: 0ºC to 45°C without derating
Mounting: Symmetrical DIN rail or bulkhead
Auxiliary Power: 115Vac or 230Vac
Cooling: 16A, 25A- convection
50A, 63A- fan cooled
{short description of image}