| POWER |
|
| Current |
|
16, 25, 40, 63, 80, 100, 125 and 160 amps three phase at 45 Deg. C |
| Voltage |
|
200 to 500VAC |
| Frequency |
|
47 to 63 Hz |
| AUXILIARY SUPPLY |
No Auxiliary supply is required as the 7300S derives its own internal,
synchronized supply |
| FAN SUPPLY |
None required up to 100 amps (natural convection). Above 100amps; 115V or 230V (10VA) |
| LOAD |
|
Three Phase industrial load: |
| Use category |
AC-51 Resistive load with low temperature coefficient |
| |
AC-55b Short wave infrared elements (for units ≤100A) |
| Load configuration |
|
Star with neutral (4S) |
| |
Star without neutral (3S) |
| |
|
Closed delta (3D) |
| |
|
Open delta (6D) |
| FUSES |
|
High speed fuses are external for thyristor ratings up to and including 100 amps, internal above 100amps
The fuses can be called up as part of the ordering code (High speed fuses not recommended for SWIR loads) |
| INPUT |
DC Logic (LDC) |
4.5 to 32 VDC (ON > 4.5V, OFF < 2V) or (ON > 9mA, OFF < 0.5mA) 32VDC maximum. |
| |
AC Logic (HAC) |
100 to 230VAC (ON > 85VAC, OFF < 10VAC) 253VAC maximum. Impedance 7K at 50 Hz |
| DC analogue (ATP) |
4-20mA (10VDC max.) |
| FIRING MODE |
|
For Logic inputs the firing is ON/OFF with zero voltage switching. |
| |
|
For analogue 4-20mA input the firing mode is Fast Cycle firing. The cycle time at 50% demand is 0.6 seconds (0.3 seconds ON and
0.3 seconds OFF). Output linearity better than + or - 2%. Open loop control (no supply voltage compensation) |
| INDICATION |
|
Green LED for supply ‘ON’. Green LED for Heat ‘ON’. Plus a range of diagnostic indicators |
| ALARMS (OPTION) |
|
| Diagnostic alarms (DLF) |
Serious Alarms: Unit overtemperature, thyristor short circuit and load open circuit signalled by set LED and relay contact
Partial load failure: Detects the failure of at least 1 element out of 4 in 3S, 4S, 6D configuration and 1 element out of 3 in 3D
configuration signalled by DLF LED and relay contact |
| ENVIRONMENT |
|
|
| Temperature |
|
Operating: 0 to 45 Deg. C. (2,000 metres maximum altitude). Storage: -10 to 70 Deg. C |
| Humidity |
|
5 to 95% Non condensing, non streaming |
| Pollution |
|
Pollution degree 2 |
| Enclosure protection |
IP20 without additional protection |
| Cooling |
|
Natural convection up to 100 amps, fan cooled >100amps |
| Heat dissipation |
|
1.3W per amp, per phase (≤2W if internal fuse) |
| Over-voltage |
|
Installation category II |
| INSTALLATION |
|
|
| Mounting |
|
Rating from 16 to 40A: Two symetric DIN rail EN50022 or bulkhead mounting (4 x M4 screws) |
| |
|
Rating from 63 to 100A: Bulkhead mounting (4 x M4 screws) |
| |
|
Rating from 125 to 160A: Bulkhead mounting (4 x M6 screws) |
| |
|
Allow a minimum of 10mm between units. Units must be mounted with fins running vertically |
| Max. cable size |
|
16 and 25 amp: 6mm2. 40 and 63 amp: 16mm2. 80 and 100 amp: 35mm2 125 and 160A: 120mm2 |
| PRODUCT STANDARD |
The 7300S products comply with the terms of product standard EN 60947-4-3. Contactors and motor-starters- AC semiconductor
controllers and contactors for non-motor loads |
| CE LABELLING |
|
7300S units installed and used according to user instructions and comply with the requirements of the European Low Voltage Directive
73/23EEC (93/68 EEC) and product standards. This enables the installation in which the products are used to be declared compliant with the
EMC directive, as regards the 7300S units. |
| WARRANTY |
|
2 years |
| PHYSICAL DATA |
| Rating (A) |
H(mm) |
W(mm) |
D(mm) |
| Basic |
GRF |
DLF |
| 16-63 |
220 |
96 |
164 |
189 |
214 |
| 80-100 |
305 |
144 |
295 |
295 |
372 |
| 125-200 |
468 |
144 |
295 |
295 |
372 |
|