- Home - Site Map - Links - Contact Us - About Us - Get In The Loop Search our site:  
7300S True Three Phase Solid State Contactor

TECHNICAL SPECIFICATIONS
{short description of image}
POWER  
Current   16, 25, 40, 63, 80, 100, 125 and 160 amps three phase at 45 Deg. C
Voltage   200 to 500VAC
Frequency   47 to 63 Hz
AUXILIARY SUPPLY No Auxiliary supply is required as the 7300S derives its own internal, synchronized supply
FAN SUPPLY None required up to 100 amps (natural convection). Above 100amps; 115V or 230V (10VA)
LOAD   Three Phase industrial load:
Use category AC-51 Resistive load with low temperature coefficient
  AC-55b Short wave infrared elements (for units ≤100A)
Load configuration   Star with neutral (4S)
  Star without neutral (3S)
    Closed delta (3D)
    Open delta (6D)
FUSES   High speed fuses are external for thyristor ratings up to and including 100 amps, internal above 100amps The fuses can be called up as part of the ordering code (High speed fuses not recommended for SWIR loads)
INPUT DC Logic (LDC) 4.5 to 32 VDC (ON > 4.5V, OFF < 2V) or (ON > 9mA, OFF < 0.5mA) 32VDC maximum.
  AC Logic (HAC) 100 to 230VAC (ON > 85VAC, OFF < 10VAC) 253VAC maximum. Impedance 7K at 50 Hz
DC analogue (ATP) 4-20mA (10VDC max.)
FIRING MODE   For Logic inputs the firing is ON/OFF with zero voltage switching.
    For analogue 4-20mA input the firing mode is Fast Cycle firing. The cycle time at 50% demand is 0.6 seconds (0.3 seconds ON and 0.3 seconds OFF). Output linearity better than + or - 2%. Open loop control (no supply voltage compensation)
INDICATION   Green LED for supply ‘ON’. Green LED for Heat ‘ON’. Plus a range of diagnostic indicators
ALARMS (OPTION)  
Diagnostic alarms (DLF) Serious Alarms: Unit overtemperature, thyristor short circuit and load open circuit signalled by set LED and relay contact Partial load failure: Detects the failure of at least 1 element out of 4 in 3S, 4S, 6D configuration and 1 element out of 3 in 3D configuration signalled by DLF LED and relay contact
ENVIRONMENT    
Temperature   Operating: 0 to 45 Deg. C. (2,000 metres maximum altitude). Storage: -10 to 70 Deg. C
Humidity   5 to 95% Non condensing, non streaming
Pollution   Pollution degree 2
Enclosure protection IP20 without additional protection
Cooling   Natural convection up to 100 amps, fan cooled >100amps
Heat dissipation   1.3W per amp, per phase (≤2W if internal fuse)
Over-voltage   Installation category II
INSTALLATION    
Mounting   Rating from 16 to 40A: Two symetric DIN rail EN50022 or bulkhead mounting (4 x M4 screws)
    Rating from 63 to 100A: Bulkhead mounting (4 x M4 screws)
    Rating from 125 to 160A: Bulkhead mounting (4 x M6 screws)
    Allow a minimum of 10mm between units. Units must be mounted with fins running vertically
Max. cable size   16 and 25 amp: 6mm2. 40 and 63 amp: 16mm2. 80 and 100 amp: 35mm2 125 and 160A: 120mm2
PRODUCT STANDARD The 7300S products comply with the terms of product standard EN 60947-4-3. Contactors and motor-starters- AC semiconductor controllers and contactors for non-motor loads
CE LABELLING   7300S units installed and used according to user instructions and comply with the requirements of the European Low Voltage Directive 73/23EEC (93/68 EEC) and product standards. This enables the installation in which the products are used to be declared compliant with the EMC directive, as regards the 7300S units.
WARRANTY   2 years
PHYSICAL DATA
Rating (A) H(mm) W(mm) D(mm)
Basic GRF DLF
16-63 220 96 164 189 214
80-100 305 144 295 295 372
125-200 468 144 295 295 372
{short description of image}
Last Updated Sunday, March 26, 2006