Ratings: Current: 15A, 25A, 40A, 63A, 75A, 100A and 125A
Voltage: 120V, 240V, 415V, 440V, 480V and 500V
Dimensions (mm): 15A: 134H x 98W x 94D, t 0.6kg
25A: 134H x 98W x 130D, 0.8kg
40A/63A: 134H x 116W x 155D, 1.2kg
75A/100A/125A: 190H x 117W x 190D, 2.0kg
Load type: 425S: resistive, short wave infrared (req. REMIO)
425A: resistive (fixed or variable), short wave infrared or inductive
Inputs: 425S: DC Logic-voltage: 10V (>8V ON: <2V
OFF) 320ž or 24V (>16V ON : <2V
OFF), input impedance 1.6Kž
DC Logic-current : 20mA (>5mA ON:
<0.5mA OFF), input impedance 10ž
AC Logic-voltage: 24V (>20V ON: <6V
OFF) 2Kž or 48V (>30V ON: <10V OFF),
input impedance 3Kž 240V (>90V ON:
<35V OFF), input impedance 9.3Kž
425A: DC voltage: 0-5V (70K), 1-5V (75K), 0-
10V (85K) use 0-5V for manual control
DC current: 0-5mA (impedance 1K), 0-
10mA (imp. 470ž), 0-20mA (imp. 270ž),
4-20mA (imp. 270ž)
Firing mode: 425S: zero voltage switching
(synchronized to line)
425A: fast cycle, single cycle, slow cycle and
phase angle (with optional current limit)
Operating temp: 0°C to 45°C
Mounting: Panel, symmetrical or asymmetrical DIN rail