General info Description Specification tab_download
SSP3 Panel Mount SSRs

Simple, safe and robust screw terminals

  • Simple and easy wiring. Allows wires with all kinds of terminations (cable ends, fork lug, ring lug).
  • Safe and fool-proof design with IP 20 protection and integrated enclosure.
  • Robust self-aligned screw terminals with proven effectiveness in preventing screw jams.

Simplified installation and mounting

  • Product option with ready factory-fit thermal pad.
  • Heat sink provides Panel and DIN rail mounting options.
 

SSP3 Panel Mount Quote

Product Code: SSP3
Qty:  
Filter by
File Name Size Updated
Mechanical Details
Cut-out dimensions
Features
Ambient Air Temperature for Operation
-40...80 °C
Ambient Air Temperature for Storage
-40...125 °C
Connections - Terminals
Screw terminals : 1 x 1.5...1 x 10 mm², (AWG 16...AWG 8) for output Screw terminals : 1 x 0.2...1 x 2.5 mm², (AWG 24...AWG 14) for input
Contacts Type and Configuration
3 NO
Control Circuit Voltage
4-32VDC, 18-36VAC, 90-140VAC, or 180-280VAC
Control Type
Without Test Button
Depth
35.4 mm
Dielectric Strength
4 kV AC for input or output to case 4 kV AC for input/output
DV/Dt
500 V/μs Off-State at Maximum Voltage
Flame Retardance
V0 conforming to UL 94
Height
79.7 mm
Insulation Resistance
>= 1000 MOhm at 500 V DC
IP Degree of Protection
IP20
Leakage Current
<= 3 mA off-state
LED Indicator
LED green for input status
Load Current
0.1...25 A, or 0.1…50 A
Marking
CE
Maximum Capacitance
<= 8 pF for input/output
Mounting Support
Panel
Number of Phases
3 Phases
Output Voltage
48...530 VAC
Overvoltage Category
III
Pollution Degree
2
Power Factor
>= 0.5 With Maximum Load
Product Certifications
CSA RoHS UL REACH
Product End of Life Instructions
Available
Product Enviromental Profile
Available
Product Weight
0.36 kg
REACh
Reference not containing SVHC above the threshold
RoHS (date code:YYWW)
Compliant - since 1328
Solid State Output Type
Random Voltage Switching or Zero Crossing
Standards
IEC 61000 IEC 60950-1 IEC 62314
Sustainable Offer Status
Green Premium product
Tightening Torque
1.7...2.2 N.m for output 0.9...1.1 N.m for input
Transient Overvoltage
1200 V
Voltage Drop
<= 1.35 V on-state
Width
101.3 mm
New power knowledge white paper

The benefits of two-leg versus three leg power control, in three phase heating applications

Download here

nanodac now with batch recording

The latest release of firmware for the nanodac features batch records.

Find out more

Webserver Access

 

  • EtherNet/IP Client or Server mode
  • IP66 Washdown Front, DDD Option (3 x Isolated DC Outputs)
  • Program Select Enhancements
  • Webserver
  • OEM Security Enhancements
  • 1 x Logic I/O, 2 x Isolated DC Outputs (LDD option).
NEW – Achilles CRT Level 1 Certification

TUS Software Tutorial
Get the most from your process
Video Tutorials
Schneider Electric. All rights reserved.© 2017