  2132i 3216i 32h8i 3204i 2408i
Panel Sizes 1/32 DIN, 24mm x 48mm 1/16 DIN, 48mm x 48mm 1/8 DIN, 48mm x 96mm 1/4 DIN, 96mm x 96mm 1/8 DIN, 48mm x 96mm
IP Rating IP65 IP65, Nema 4X IP65 Nema 4X IP65 Nema 4X IP65
Display Type 4 Digit LED 4 Digit LCD plus 5 character alphanumeric 5 Digit LCD plus 9 character alphanumeric 4 Digit LCD plus 5 character alphanumeric Large 5 digit LED
Supply Voltage 100 - 264Vac, 24Vac/dc 100 - 264Vac, 24Vac/dc 100 - 264Vac, 24Vac/dc 100 - 264Vac, 24Vac/dc 100 - 264Vac, 24Vac/dc
Factory Mutual   Yes Yes Yes  
DIN 3440   Yes Yes Yes  
PV Inputs 1 1 1 1 2
Input Types TC, RTD, mV, mA, Custom TC, RTD, mV, mA, Volts, Custom TC, RTD, mV, mA, Volts Custom TC, RTD, mV, mA, Volts, Custom TC, RTD, mV, mA, Volts, Custom
PV Accuracy Better than 0.25% of reading Better than 0.25% of reading Better than 0.25% of reading (0.1% for strain gauge) Better than 0.25% of reading Better than 0.2% of reading
User Calibration 2 point 5 point 5 point, shunt, load cell, auto tare 5 point 15 point, shunt, load cell, comparison, auto tare
Derived PV input         Yes
PV Input Selection         Hi, Lo, Select, Switchover
Alarm Output Types Logic, relay Logic, relay, analogue Logic, relay, analogue Logic, relay, analogue Logic, relay, triac, analogue
No of Alarms 3 4 4 4 8
Alarm Types Hi, Lo, Dev, sensor break Hi, Lo, Dev, event, sensor break, rate of change Hi, Lo, Dev, event, sensor break, rate of change Hi, Lo, Dev, event, sensor break, rate of change Hi, Lo, Dev, event, sensor break, rate of change, event
No of Relay Outputs 2 3 2 2 7
Retransmission Yes (non-isolated) Yes (isolated) Yes (isolated) Yes (isolated)
Digital Inputs 1 2 2 2 2 plus possible further 9
Logic Outputs 2 2 0 0 9 with modules
Recipes   5 with 19 tags 5 with 19 tags 5 with 19 tags  
Custom Messages   Yes (128 Characters) Yes (128 Characters) Yes (128 Characters)  
Custom Pages Operator list Operator list Operator list Operator list Operator list
Slave Communications   Modbus RTU Modbus RTU Modbus RTU Modbus RTU, Devicenet, Profibus DP, EI-Bisync
Master Communications   1 parameter broadcast 1 Parameter broadcast 1 Parameter broadcast  
Melt Pressure     Yes    
5/10Vdc Transducer PSU     Yes (10Vdc)    
24Vdc Transmitter PSU     Yes Yes  