TECHNICAL SPECIFICATION (7EM) |
| Case: |
|
|
ABS black.
Self-extinguishing degree V-0 according to UL, VDE and CSA. |
| Front Protection: |
|
Designed and tested for IP54 according to IEC 529 and CEI
70-1. |
| Installation: |
|
|
Panel mounting by
means of brackets. |
| Rear Terminal Block: |
|
|
Up to 21
screw terminals, with safety rear cover. |
| Dimensions: |
|
48 x 96 mm (1.890 x 3.780 in.)
according to DIN 43700; 89 mm (3.504 in.) deep. |
| Weight: |
|
400 grams
maximum (1 pound). |
| Power
Supply (Switch Mode): |
|
- 100 to 240 Vac. 50/60 Hz
(10% to -15% of the nominal value). |
|
|
|
- 24
Vac/Vdc. (±10% of the nominal value). |
| Power
Consumption: |
|
11 VA. |
| Insulation Resistance: |
|
Greater than
2 GW for 500 Vdc according to IEC 348. |
| Isolation
Voltage: |
|
|
1500 Vrms according to IEC
348. |
| D/A Conversion: |
|
|
Dual slope
integration. |
| Noise
Immunity: |
a) |
|
Electrical fast
transient/burst requirements: Severity Level 3 (according to IEC 801-4). |
|
b) |
|
Electric
discharge requirements: Severity Level 8 (according to IEC 801-2). |
| Sampling
Time: |
|
|
500 ms. |
| Accuracy: |
|
|
±0.2%
full scale span or ±1°C, @ 25 °C and nominal power supply
voltage. |
| Common Mode Rejection Ratio: |
|
120 dB @ 50/60 Hz. |
| Normal Mode Rejection Ratio: |
|
60 dB @
50/60 Hz. |
| Operating Temperature: |
|
From 0 to 50 °C. |
| Storage Temperature: |
|
From -20 to
70 °C. |
| Humidity: |
|
|
From 20% to 85% RH
non-condensing. |
| Protection: |
|
|
Internal
jumper for configuration and calibration parameters. |
Control
Action |
| On/Off, PID or Smart AT Autotuning |
|
|
| Special
Function: |
|
|
Standby alarm sequence. |
Inputs (All inputs are factory calibrated and selectable from the
keyboard.) |
| Types: |
|
|
Thermocouples (J, K, L, N, T)
or RTD Pt 100, keyboard configurable. |
| Engineering Units: |
|
|
°C and
°F keyboard configurable. |
| Reference
Junction: |
|
|
Automatic compensation for an
ambient temperature between 0 and 50 °C. |
| Line Impedance: |
|
|
100
W maximum for TC input. |
|
|
|
20 W/wire maximum for RTD input. |
| Reference Junction Drift: |
|
0.1
°C/°C. |
| Input
Impedance: |
|
|
Greater than 1 MW. |
| Sensor Break: |
|
|
Downscale or
upscale programmable. On RTD inputs, an OVERRANGE is indicated when input
resistance is less than 15 W (short circuit sensor
detection.) |
| Calibration: |
|
|
According to IEC 584-1 and DIN
43710-1977. |
Current Transformer Input for OUT 1 Heater Breakdown Detection (Optional) |
| This
feature allows measurement of the load current by means of a current
transformer and signals an alarm condition when the current is below a
pre-programmed threshold value. |
| Input Range: |
|
|
50
mAac. |
| Scaling: |
|
|
Configurable from 10 Amps to
100 Amps (with a 1 Amp step). |
| Resolution: |
|
|
- for full
scale up to 20 Amps: 0.1 Amp. |
|
|
|
- for full scale from 21 Amps
to 100 Amps: 1 Amp. |
| Active Period: |
|
|
- for relay
output: NO or NC configurable. |
|
|
|
- for SSR output: logic level
1 or 0 configurable. |
| Minimum On Time to perform the measurement: |
|
50 ms. |
Outputs |
| Main Output: |
(Heating) |
|
Relay or SSR
(jumper selectable) |
|
|
|
- Relay SPDT, contact rating 3
Amps @ 250 Vac on resistive load. |
|
|
|
- Logic
output for SSR, 700 W maximum load, short circuit
protected. |
|
Logic Level 1: |
|
14 Vdc ±20% @ 20 mA
max. |
|
|
|
24 Vdc
±20% @ 1 mA max. |
|
Logic Level 0: |
|
Less than 0.5 Vdc |
| Output 2 |
|
|
(Cooling or
Alarm 1) |
|
|
|
Relay or SSR (jumper
selectable) |
|
|
|
- Relay
SPST, contact rating 2 Amp @ 250 Vac on resistive load. |
|
|
|
- Logic output for SSR, 700 W
maximum load, short circuit protected. |
|
Logic Level 1: |
|
14 Vdc
±20% @ 20 mA max. |
|
|
|
24 Vdc ±20% @ 1 mA
max. |
|
Logic Level 0: |
|
Less than
0.5 Vdc |
| Output 3 |
|
|
(Alarm 2 or Heater
breakdown) |
|
|
|
- Relay
SPST, contact rating 2 Amp @ 250 Vac on resistive load. (normally open contact
only) |
Alarms |
| Alarm Functions: |
|
|
Process
Alarm |
|
|
|
Deviation Alarm |
|
|
|
Band
Alarm |
| Type of
Alarm: |
|
|
- High/Low (Outside/Inside for
band alarm) |
|
|
|
-
Direct/Reverse |
|
|
|
- Standby Sequence/No Standby
Sequence |
| Alarm Hysteresis: |
|
|
0.1 to 10.0%
of input span or 1 least significant digit. |
| Alarm
Output: |
|
|
Relay SPST 2 Amp @ 250 Vac
resistive load. |
Display Characteristics |
| Upper
Display: |
|
|
3 digit 7 segment green LED
display; 10 mm high. |
| Lower Display: |
|
|
3 digit 7
segment orange LED display; 7.6 mm high. |
| Indicators: |
|
|
1 red LED when main (heating)
output is ON. |
|
|
|
1 red LED
when cooling (or alarm 1) output is ON. |
|
|
|
1 red LED when alarm 2 (or hbd
alarm) output is ON. |
|
|
|
1 red LED
when Smart AT is enabled. |