The 2404 Atmosphere Controllers provide
accurate display and control of carbon level in carburizing furnaces and
ceramic glazing kilns. There are three different controllers that connect to a
variety of common zirconia probes, including the Series AP from Eurotherm,
which measure the % oxygen in a furnace. The carbon level is calculated from
two inputs, the % O2 and temperature measured by the probe. An optional third
input can accept a signal from a CO or H2 analyzer, thus providing a more
precise carbon or dewpoint measurement.
In addition to carbon levels, the controller
can be configured to measure % O2, log O2, dewpoint (°C or °F) and
probe millivolts. A probe clean output forces compressed air through the probe
at regular intervals to burn off soot. A sooting alarm will warn if carbon
deposits |
|
build up to give false readings. Health of
the probe is measured by monitoring the time it takes the probe mV reading to
recover from self-clean. Probe clean and CO/H2 compensation are enabled by
digital inputs. A range of plug-in modules provide control, alarm and
retransmission options. Optional Modbus®, ASCII, or Profibus®
communications are available.
ESO209 - This low cost version offers PID and
two module slots plus Modbus® or ASCII communications. ES0288 - This
version is identical to ES0209, but with Profibus®-DPcommunications.
ES0278 - This version offers PID or valve control, two module slots, five relay
outputs, Modbus® or Profibus® communications and an optional third slot
for retransmission or CO compensation |